MasterLine LambdaCy

Manufacturer
SYNGENTA
Category
Insecticides
Registered until
Registration expired
Registration number
31300
Active materials

STORAGE
Store in a c ool, well ventilated area away from foodstuffs and out of the reach of children and animals. Store above 0 C. Shake well before use.

SPILL CLEANUP
Wear appropriate protective equipment (glove s, glasses, apron) when attempting to clean up the spill. If the containe r is leaking, secure leak and place the containe r into a dru m or heavy gauge plastic bag. Contact Syngenta Canada Inc. at 1-800-327-8633 (FASTMED) for further information.
For spills and leaks - contain the liquid with dikes of inert material (soil, clay, kitty litter etc.). Absorb the spill onto inert material and shovel into a sealable waste container.
On hard surfaces - sprinkle spill area with detergent and scrub in a small quantity of water with a coarse broom. Let sta nd 10 minut es then absorb onto an inert material and shovel into the waste container.
On soil - remove the top 15 cm of soil in the spill area and replace with fresh soil. Dispose of all waste including scrub brush in accordance with provincial requirements.

DECONTAMINATION AND DISPOSAL
For information on disposal of unused, unwanted product, contact the manufacturer or the provincial regulatory agency. Contact the manufacturer and the provincial regulatory agency in case of a spill, and for clean-up of spills.

CONTAINER DISPOSAL:
Do not reuse this container for any purpose. This is a recyclable container, and is to be disposed of at a con tainer collection site. Con tact your local dist ributor/dealer or municip ality for the location of the nearest collection site. Before taking the container to the collection site:
1. Triple- or pressure-rinse the empty container. Add the rinsings to the spray mixture in the tank.
2. Make the empty, rinsed container unsuitable for further use.
If there is no container collect ion site in your area, dispose of the container in accor dance with provincial requirements.

PRODUCT INFORMATION
MasterLine LambdaCy Insecticide is a photosta ble, synthetic pyrethroid insecticide. It is a fast acting stomach and contact insecticide effective against a broad spectrum of pests. It has no fumigant or systemic activity. Best results will be obtained with MasterLine LambdaCy Insecticide when applied against the early devel opment stages of the pest as determined by regular monitoring.

DIRECTIONS FOR USE
STRUCTURAL AND PERIMETER PEST CONTROL
ANTS: Apply to cracks and crevices around doors and windows and other places where ants may be found. For best results, locate and treat nests within structures. Where ants are trailing inside, apply as a crack and crevice treatment to active areas such a s baseboards, corners, around pipes, in and b ehind cabinets, behind and under refrigerators, sinks, fur naces and stoves. When combining baits and crack and crevice insecticides, apply insecticides in cracks and crevices along baseboards and infested surfaces. Use baits in other areas that are untreated by residual insecticides.
COCKROACHES, CRICKETS and FIREBRATS: Apply as a coarse , low pressure spray to cracks and crevices w here these pests hide, such as b aseboards, corners, storage areas, closets, around water pipes, doors and windows, attics and eaves, cabinets, behind and under refrigerators, sinks, furnaces, and stoves, the underside of shelves, drawers and similar areas.
CENTIPEDES, MILLIPEDES AND SOWBUGS: Apply around doors and windows where these pests may be found or where they may enter premises. Treat baseboards, storage areas, and other locations. Apply barrier treatments to prevent infestation as described below. (See BARRIER TREATMENT).
BED BUGS: Crevices, baseboards, loose pla ster, behind bed frames and headb oards, and beneath beds and furniture. Do not apply to furniture surfaces or mattre sses where people will be laying or sitting. Infe sted bedding should not be treated, but should be removed , placed in sealed plastic bags, and taken for laundering and drying at high temperatures.
Application Within Food Handling Establishments: (places other than private residences in which exposed food is held, processed, prepared, or served) including, but not limited to, areas for receiving, storage, packing (canning, bottling, wrapping, boxing), preparing fo ods, edible waste storage and enclosed processing systems (mills, dairies, edible oils, syrups) and serving areas. Use as a crack and crevice treatment in and around both food and non-food areas.
Apply in small amounts directly into cracks and crevices, using equipment capable of delivering a pin-stream spray, in points bet ween different elements of constru ction, between equipment and floor, openings leading to voids and hollow spaces in walls, equipment and bases. Food contact surfaces and equipment should be cleaned with an effective cleaning compound and rinsed with potable water before using.
Take extreme care tha t the product is not intro duced into the air. Avoi d contamination of food and food processing surfaces.
Application Within Food Serving Areas: (facilities where foods are served, such as dining rooms): Apply as a crack and crevice treatment. Avoid tre ating areas likely to be contacted by food. (Do not apply wh en facility is in operation or foods are exposed.) Food must be covered or removed in area be ing treated. Do not a pply directly to food or allow applications to contaminate food.
ANY TREATED SURFACE THAT MAY CONTACT FOOD PRODUCTS SHOULD BE WASHED AND RINSED THOROUGHLY WITH POTABLE WATER BEFORE USE. Use of application equipment such a s the Micro-Injector or Actisol applicator in food areas should b e limited to crack and crevice treatment only.
BARRIER TREATMENT: For co ntrol of ant s, crickets, millipedes and sowb ugs apply a continual band of insecticide solution around a building foundation and around windows, doors, service line entrances, eaves, vents and other areas with potential for entry by crawling pests. To facilitate application, remove debris and leaf litter from next to the foundation, cut back vegetation and branches that touch t he foundation, and move or rake ba ck rocks, deep mulch, or other pot ential pest harborage next to the foundation. Apply the b and up to 3 .0 m wide around the structure and upwards along the foundation to 0.9 m and around windows, doors, and roof overhangs. A pply as a coarse spray to thorough ly and uniformly wet th e foundation and/or band area so that the insecti cide will reach the soil or thatch level where pests may be active.
NOTE: Do not use water base sprays of MasterLine LambdaCy Insecticide in conduits, motor housings, junction boxes, switch boxes, or other electrical equipment because of possible shock hazard. For best re sults, thoroughly wash out sprayer and screen with water and detergent before using MasterLine LambdaCy Insecticide. MasterLine LambdaCy Insecticide has not stained or caused damage to painted or varnished surface s, plastics, fabrics or other surfaces where water applied alone causes no damage.
- Do not apply this produ ct in any room being used as living, eating, sleeping or recovery area by patients, the elderly, or infirm when they are in the room.
- Do not apply this product to edible growing crops or stored raw agricultural commodities used for food or feed.
- Do not allow applications to contact water inhabited by fish, such as in aquariums and ornamental fish ponds that are located in/around structures being treated. 

Mixing Instructions
MasterLine LambdaCy Insecticide is intended for dilution with water for application using hand held or po wer operated application equipment as a coarse spray for crack and crevice treatments. Application equipment that delivers low volume treatments, such as the Micro - Injector or Actisol applicator, may also be used to make crack and crevice treatments. Fill applicator tank with the desired volume of water and add MasterLine LambdaCy Insecticide. Close and shake before use in order to ensure proper mixing. Shake or re-agitate applicator tank before use if application is interrupted. Mix only amount of treatment volume as required.