Spectrum 350 SC
- Manufacturer
- PCT holdings
- Category
- Insecticides
- Registered until
- 2029-06-29
- Registration number
- 66265
- Active materials
- imidacloprid200 g/l
- Links
- LabelView
GENERAL INSTRUCTIONS (AGRICULTURAL APPLICATIONS):
MIXING/APPLICATION:
- Shake the container vigorously before pouring.
- Add the required quantity of Surefire Spectrum 200SC Insecticide to water in the spray vat while stirring or with agitators in motion.
DILUTE SPRAYING (STONE FRUIT):
- Use a sprayer designed for high water volumes up to the point of run-off.
- Set up and operate the sprayer for even coverage throughout the crop canopy.
- Apply water to cover the crop to the point of run-off.
- Determine the required water volume by testing different volumes based on guidelines or expert advice.
- Add the product per 100 L of water specified in the Directions for Use table. Spray to the point of run-off.
- Adjust dilute spray volume, sprayer setup, and operation as the crop grows.
CONCENTRATE SPRAYING (STONE FRUIT):
- Use a sprayer designed for concentrate spraying.
- Set up and operate the sprayer for even coverage throughout the crop canopy.
- Determine an appropriate dilute spray volume for the crop canopy.
- Calculate the concentrate mixing rate using the concentration factor.
- Adjust spray volume, product amount per 100 L of water, and sprayer setup as the crop grows.
- Do not exceed the concentrate rate specified in Critical Comments.
APPLICATION (COTTON):
- Ensure thorough coverage of cotton plants.
- Calibrate equipment to achieve a minimum of 60 droplets/cm² on the target foliage.
- Droplet Volume Median Diameter (VMD) for optimum performance is dependent on equipment and should be within specified ranges.
- Do not apply under unfavorable environmental conditions that may reduce spray coverage.
GROUND APPLICATION (COTTON):
- Use hollow cone nozzles with a minimum spray volume of 100 L/ha.
- Droplet VMD of 150 - 180 microns is recommended.
- Ensure multiple nozzles per row are of the same specification for equal dose contribution.
- Avoid banded applications less than 100% beyond the 15 node crop stage.
AERIAL APPLICATION (COTTON):
- Apply in a minimum spray volume of 25 L/ha.
- Droplet VMD of 120 - 150 microns must be used.
- Do not exceed a swath width of 20 to 22 m.
- Do not use Ultra Low Volume (ULV) methods.
APPLICATION (APPLES):
- Identify and mark apple trees with woolly aphid colonies during late summer or autumn.
- At green tip to petal fall, apply 1 liter of the prepared Surefire Spectrum 200SC Insecticide mixture to moist soil around the tree trunk.
- Ensure infiltration into the soil without runoff. Control weeds before application.
- Do not disturb or remove the soil around the trunk during the season.
NOTE ON ORNAMENTALS:
- Test Surefire Spectrum 200SC Insecticide on a small number of ornamental plants before treating the entire crop.
- Some species and varieties may be sensitive to chemical sprays.
COMPATIBILITY:
- Surefire Spectrum 200SC Insecticide is compatible with Antracol®, Baycor®, and Nitofol®.
- Do not mix concentrates together; add each to the spray tank separately.
- Test mixtures before using commercial quantities.
GENERAL INSTRUCTIONS (TERMITICIDE TREATMENTS):
PROGRAM STEPS:
- Locate and treat the termite nest where possible.
- Repair leaks and improve ventilation under structures.
- Ensure sub-floor areas are kept free of stored or waste timber.
- Apply the soil treated zone.
- Advise against disturbing the treated zone.
- Continue efforts to locate and treat the termite colony in the nest.
- Perform post-treatment inspection to confirm success.
- Conduct ongoing inspections, at least annually.
MIXING:
- Thoroughly clean spray equipment before using Surefire Spectrum 200SC for the first time.
- Shake the container vigorously before pouring.
- Premix the required quantity of Surefire Spectrum 200SC with water in a clean bucket before adding it to the half-filled spray tank, then top up to full volume. Allow tank contents to be recirculated.
SOIL PREPARATION:
- Loosen soil before treatment, especially in difficult wetting conditions.
- Create a trench to confine the spray solution to the treatment area.
- Add a wetting agent if necessary.
THICKNESS OF TREATED ZONE:
- Minimum recommended thickness of any soil treated zone is 100 mm.
TREATMENT OF EXISTING BUILDINGS (TERMITES):
- Follow Australian Standard AS3660 Series for procedures.
- Ensure no gaps in treatment.
TREATMENT OF NEW BUILDINGS (TERMITES):
- Surefire Spectrum 200SC cannot be used for horizontal barrier-type treated zones prior to pouring a slab unless used in a certified reticulation system.
- Initial under-slab treatment through the reticulation system should occur after a 28-day period following slab placement but not more than 60 days after placement.
RETICULATION SYSTEMS (TERMITES):
- Must establish and maintain complete and continuous treated zones.
- Reticulation systems must be certified as meeting AS3660 by suitable persons or organizations with relevant expertise.
- The system must allow the application of a minimum 100 mm thick treated zone.
- Communication with the builder and sub-contractor is recommended to ensure proper installation according to specifications.
ALTERATIONS TO BUILDINGS:
- Drainage, ventilation, and timber/soil contact problems need to be addressed before treatment to increase effectiveness.
Registered for cultures | Rate |
---|---|
Cotton | 0 l |
Apples | 0 l |
Eggplant | 0 l |
Potatoes | 0 l |
Tomatoes | 0 l |
Sweet potatoes | 0 l |
Cucumbers | 0.25 l |