Masterline I Maxxpro 2F

Manufacturer
Univar
Category
Insecticides
Registered until
N/A
Registration number
73748-9
Active materials
Links

DIRECTIONS FOR USE
It is a violation of Federal law to use this product in a manner inconsistent with its labeling.
See individual sites for specific pollinator protection application restrictions. If none exist under the specific site, for outdoor foliar applications, follow these application directions

INFORMATION
I MAXXPRO 2F may be applied as an insecticidal barrier to control and prevent infestations of subterranean termites in and around structures and constructions, in order to establish a barrier between the structure and the termites in the self, the insecticide emulsion must be adequately dispersed In the soil.
For best results, applicators must be familiar with current termite control practices. These practices include trenching, rod ding, sub-slab injections, coarse fan spraying of soil surfaces, crack and crevice (void) injection, and excavated soil treatment. Determining which control practices to use is dependent upon the biology and behavior of the species involved. The standards for subterranean termite control may vary due to regulations, treatment procedures, soil types, construction practices and other factors. Be sure to follow all federal, state and local regulations and treatment standards for protection of structures from termites. Based on local recommendations, use a 0.05% for typical situations and a 0.10% dilution in cases of severe or persistent infestations.
Proper application of I MAXXPRO 2F will provide a continuous barrier between the wood and other cellulose material in the structure and the termite colonies in the soil. In some instances where an aerial or an above ground colony is established, supplemental treatments to control the termites, landscape modifications, and / or structural repairs may be needed to deprive the termites of a moisture source.
Structures that contain wells or cisterns within the foundation of the structure can only be treated using the treated backfill method described in the treatment around wells and cisterns section of this label. Consult state and local specifications for recommended distances of wells from treated area, or if such regulations do not exist, refer to Federal Housing Administration
Specifications (H.U.D.) for guidance.

MIXING DIRECTIONS
To Mix:
1. Fill tank 1/4 to 1/3 full.
2. Start pump to begin by-pass agitation and place end of treating tool in tank to allow circulation through hose.
3. Add appropriate amount of I MAXXPRO 2F (see table below).
4. Add remaining amount of water.
5. Let pump run and allow recirculation through the hose for 2 to 3 minutes.

APPLICATION INSTRUCTIONS
Refer to the appropriate section below for specific application instructions. For best results, remove all non-essential wood and cellulose containing material from around crawlspaces, foundation wails, and porches. In order to eliminate termite access to moisture, repair faulty plumbing and/or construction grade.
NOTE: Definition of Critical Areas: Critical areas include areas where the foundation is penetrated by utility services, cracks and expansion joints, bath traps and areas where cement constructions have been "poured adjacent to the foundation as stairs, patios and slab additions.
Application Volume: To provide maximum control and protection against termite infestation, apply the specified volume of the finished water emulsion and active ingredient as set forth in the directions for use section of this label. If soil will not accept the labeled application volume, the volume may be reduced provided there is a corresponding increase in concentration so that the amount of active ingredient applied to the soil remains the same.
Note: Large reductions of application volume reduce the ability to obtain a continuous barrier. Variance is allowed when volume and concentration are consistent with label directed rates and a continuous barrier can still be achieved.

Use Restrictions:
• Plug and fill all holes drilled in concrete slab areas of the building with a suitable sealant after treatment
• Do NOT apply until the location of all heat pipes, ducts, electrical conduits and water and sewer lines are identified.
• Do NOT plant edible plants for consumption in soil that has been treated.
• Do NOT contaminate public or private water supplies, wells and cisterns.
• ALL leaks of I MAXXPRO 2F applications into areas not prescribed on this label must be cleaned up prior to leaving the application site.
• Do NOT allow people or pets to come into contact or to reoccupy contaminated areas until clean up is completed.
• All filling hoses must have an air gap or use anti-backfiow equipment.
• Do not treat soil that is water saturated or frozen or in any conditions where runoff or movement from the treatment area (site) is likely to occur.
• Do not treat while precipitation is occurring.
• Do not apply to effluent discharge systems such as leach beds, French drains or sumps.
• All holes in commonly occupied areas into which material has been applied must be plugged. Plugs must be of a noncellulose material or covered by an impervious, non-cellulose material. Note: Crawlspaces are to be considered inside of the structure.

Use Precautions:
• The applicator must take into account structural design considerations and potential post-application effects from heating, ventilation and air conditioning systems (HVAC) when applying I MAXXPRO 2F indoors.
• The applicator must take into account soil type, soil compaction, grade conditions, utilities and location and type of domestic water supply when applying I MAXXPRO 2F outdoors.
• Use anti-backflow equipment or procedures to prevent siphonage of this product into water supplies in order to prevent contamination of public and private water supplies.
• Consult state and local specifications for recommended distances of wells from treated areas, or if such regulations do not exist, refer to Federal Housing Administration Specifications (H.U.D.) for guidance. When applying in close proximity to potable water supplies, consult state, Federal or local authorities for information regarding approved treatment practices.
When treating adjacent to an existing structure, the applicator must check the area to be treated, and immediately adjacent areas of the structure, for visible and accessible cracks and holes to prevent any leaks or significant exposures to persons occupying the structure. People present or residing in the structure during application must be advised to remove their pets and themselves from the structure if they see any signs of leakage. After application, the applicator is required to check for leaks. All leaks resulting in the deposition of termiticide in locations other than those prescribed on this label must be cleaned up prior to leaving the application site.

Registered for cultures
Pome fruits
Pecans
Grapes