Optane LV 680

Manufacturer
Ruralco
Category
Herbicides
Registered until
2024-06-29
Registration number
81788
Active materials
Links


GENERAL INSTRUCTIONS
Before opening, carefully read DIRECTIONS FOR USE, PROTECTION OF CROPS, NATIVE AND OTHER NON TARGET PLANTS, SAFETY DIRECTIONS and FIRST AID Instructions.

APPLICATION INFORMATION This product may be used in either high or low volume sprays. Just pour into water and stir.

  • Boom Spraying Use 30-120 litres water/ha.

  • Aerial Spraying Use 10-90 litres water/ha. Note: Refer to the Department of Agriculture / Primary Industries in your state for the current restricted spraying areas.

EQUIPMENT MAINTENANCE AND USAGE Keep the spray unit for herbicides only if possible. Otherwise wash out the unit with hot soapy water followed by several clear water rinses. DO NOT use wooden spray vats as they cannot be cleaned. Hoses cannot be cleaned and new hoses should be fitted when the unit is to be used for any other purpose.

COMPATIBILITY This product can be tank mixed with atrazine, dicamba, chlorsulfuron, triclopyr, glyphosate, metsulfuron-methyl, paraquat, paraquat/diquat, fluroxypyr and triasulfuron. NOTE:

  1. As formulations of other manufacturers’ products are beyond the control of Nutrien Ag all mixtures should be tested on a small scale before mixing in the spray tank.

  2. Tank mixing instructions: Fill the spray tank 1/4 full of water and agitate. Add wettable powders and water dispersible granules first. Agitate until these are uniformly dispersed, meanwhile adding water until the tank is 90% full. Add suspension concentrates (flowables) then soluble concentrates. Emulsifiable concentrates go in last. Top off the tank with water and continue agitation until all the ingredients are properly mixed. Observe any mixing sequence instructions mentioned on the tank mix products.

Resistance Warning: RESISTANT WEEDS WARNING GROUP I HERBICIDE Relyon 2,4-D LV Ester 680 Herbicide (Relyon 2,4-D LV Ester 680 Herbicide) is a member of the phenoxys group of herbicides. Relyon 2,4-D LV Ester 680 Herbicide has the disruptors of plant cell growth mode of action. For weed resistance management Relyon 2,4-D LV Ester 680 Herbicide is a Group I herbicide. Some naturally occurring weed biotypes resistant to Relyon 2,4-D LV Ester 680 Herbicide and other Group I herbicides may exist through normal genetic variability in any weed population. The resistant individuals can eventually dominate the weed population if these herbicides are used repeatedly. These resistant weeds will not be controlled by Relyon 2,4-D LV Ester 680 Herbicide or Group I herbicides. Since the occurrence of resistant weeds is difficult to detect prior to use, Nutrien Ag Solutions Limited accepts no liability for any losses that may result from the failure of Relyon 2,4-D LV Ester 680 Herbicide to control resistant weeds.

Precautions: RE-ENTRY PERIOD DO NOT hand harvest sugar cane for at least 1 day after application. If re-entering treated areas before the spray has dried, workers should wear overalls, elbow-length gloves and water-resistant footwear. Clothing must be laundered after each day's use.

Protections: PROTECTION OF CROPS, NATIVE AND NON-TARGET PLANTS DO NOT apply under weather conditions, or from spraying equipment, that may cause spray to drift onto nearby susceptible plants/crops, cropping lands or pastures. Avoid spray drift and vapour movement onto susceptible crops such as cotton, tobacco, tomatoes, vines, lupins, fruit trees and ornamentals.

PROTECTION OF WILDLIFE, FISH, CRUSTACEANS AND ENVIRONMENT Very toxic to aquatic life. DO NOT contaminate wetlands or watercourses with this product or used containers. INTEGRATED PEST MANAGEMENT Toxic to beneficial arthropods. Not compatible with integrated pest management (IPM) programs utilising beneficial arthropods. Minimise spray drift to reduce harmful effects on beneficial arthropods in non-crop areas.

Storage and Disposal: Store in the closed, original container in a cool, well-ventilated area. DO NOT store for prolonged periods in direct sunlight. Triple-rinse containers before disposal. Add rinsings to spray tank. Do not dispose of undiluted chemicals on site. If recycling, replace cap and return clean containers to recycler or designated collection point. If not recycling, break, crush, or puncture and deliver empty packaging to an approved waste management facility. If an approved waste management facility is not available, bury the empty packaging 500 mm below the surface in a disposal pit specifically marked and set up for this purpose, clear of waterways, desirable vegetation and tree roots, in compliance with relevant local, state or territory government regulations. Do not burn empty containers or product. This container can be recycled if it is clean, dry, free of visible residues and has the drumMUSTER logo visible. Triple-rinse container for disposal. Dispose of rinsate by adding it to the spray tank. Do not dispose of undiluted chemical on site. Wash outside of the container and the cap. Store cleaned container in a sheltered place with cap removed. It will then be acceptable for recycling at any drumMUSTER collection or similar container management program site. The cap should not be replaced, but may be taken separately. Refillable Containers (110 L, 1000 L): Empty contents fully into application equipment. Close all valves and return to point of supply for refill or storage.

Registered for culturesRate
Potatoes1.15 - 2.4 l
Sugarcane1.15 - 2.4 l
Winter triticale0.21 - 0.8 l
Spring triticale0.21 - 0.8 l
Winter barley0.21 - 0.8 l
Spring barley0.21 - 0.8 l
Winter wheat0.21 - 0.8 l
Spring wheat0.21 - 0.8 l