ARGYLE OD
- Manufacturer
- UPL
- Category
- Insecticides
- Registered until
- N/A
- Registration number
- 70506-346
- Active materials
- bifenthrin1.52 lb/gallon
- acetamiprid1 lb/gallon
DIRECTIONS FOR CHEMIGATION APPLICATIONS
For chemigation use only on soybeans after foliage has emerged and only through overhead sprinkler irrigation systems. Apply this product only through overhead irrigation systems including center pivot, lateral move, side (wheel) roll, solid set, or hand move irrigation systems after soybean foliage has emerged. Do not apply this product through any other type of irrigation system. Do not connect an irrigation system (including greenhouse systems) used for pesticide application to a public water system. The set up and calibration of chemigation equipment are important to achieve control of target insect pests. Crop injury, lack of effectiveness, or illegal residues in the crop can result from non-uniform distribution of treated water. Contact your State Agricultural Extension Service specialists, equipment manufacturers or other experts for advice on the suitability of the equipment set up for optimum control of the target insect pests. A person knowledgeable of the chemigation system and responsible for its operations, or under the supervision of the responsible person, shall shut the system down and make necessary adjustments should the need arise. Failure to cease application during a mechanical stoppage may result in undesirable residues to adjacent areas. The overhead sprinkler chemigation system must contain a functional check valve, vacuum relief valve, and low pressure drain appropriately located on the irrigation pipeline to prevent water source contamination from back flow. The pesticide injection pipeline must contain a functional, automatic, quick-closing check valve to prevent the flow of fluid back toward the injection pump. The pesticide injection pipeline must also contain a functional, normally closed, solenoid-operated valve located on the intake side of the injection pump and connected to the system interlock to prevent fluid from being withdrawn from the supply tank when the irrigation system is either automatically or manually shut down. The system must contain functional interlocking controls to automatically shut off the pesticide injection pump when the water pump motor stops. The irrigation line or water pump must include a functional pressure switch which will stop the water pump motor when the water pressure decreases to the point where pesticide distribution is adversely affected. Systems must use a metering pump, such as a positive displacement injection pump (e.g. diaphragm pump) effectively designed and constructed of materials that are compatible with pesticides and capable of being fitted with a system interlock. Do not apply when wind speed favors drift beyond the area intended for treatmen
APPLICATION INSTRUCTIONS
Follow the requirements in the System Requirement section above. Apply ARGYLE OD Insecticide only through systems containing anti-siphon and check valves designed to prevent water source contamination or overflow of the mix tank and containing interlocking controls between the metering device and the water pump to insure simultaneous shut-off. Maintain a gentle continuous agitation in mix tank during mixing and application to assure a uniform suspension. Greater accuracy in calibration and distribution will be achieved by injecting a larger volume of a more dilute suspension per unit time. Application of more than recommended quantities of irrigation water per acre may result in decreased product performance. Do not apply when wind speed favors drift, when system connections or fittings leak, when nozzles do not provide uniform distribution or when lines containing the product cannot be flushed and must be dismantled and drained. In a center pivot system, block the nozzle set nearest the well/pivot/ injection unit to prevent spray being applied to this area. Use of end guns which deliver uneven distribution of water is not recommended. Where sprinkler distribution patterns do not overlap sufficiently, unacceptable insect control may result. Allow sufficient time for pesticide to be flushed through all lines and all nozzles before turning off irrigation water. ARGYLE OD Insecticide may be applied in conjunction with chemically neutral liquid fertilizers. Application in conjunction with highly alkaline fertilizers, such as aqueous ammonia, may cause a degradation of the pesticide, resulting in reduced performance and should be avoided.
APPLICATION INSTRUCTIONS
Follow the following minimum water volumes per acre by crop type unless otherwise specified differently in an individual crop section.
Spray Volumes - Cotton and Soybeans Apply ARGYLE OD Insecticide in a minimum finished spray volume of 3 gallons per acre by aircraft and 10 gallons per acre by ground equipment. Under extreme pest populations or dense foliage, use a minimum spray volume of 5 gallons per acre by air.
Spray Volumes - All Other Crops Apply ARGYLE OD Insecticide in a minimum finished spray volume of 5 gallons per acre by aircraft and 20 gallons per acre by ground equipment. Under extreme pest populations or dense foliage, increase water volume.
| Registered for cultures | Rate |
|---|---|
| Cotton | 5 - 9 fl oz |
| Soybeans | 5 - 9 fl oz |
| Strawberries | 4 - 16 fl oz |