- Active materials
- bifenthrin1.5 lb/gallon
DIRECTIONS FOR USE
RESTRICTED USE PESTICIDE It is a violation of Federal law to use this product in a manner inconsistent with its labeling Do not apply this product in a way that will contact workers or other persons, either directly or through drift Only protected handlers may be in the area during application For any requirements specific to your State or Tribe, consult the agency responsible for pesticide regulation This labeling must be in the possession of the user at the time of pesticide application
RESISTANCE MANAGEMENT
Suro LFC contains a chemical classified as a Group 3A insecticide Some pest populations have been known to develop resistance There is potential risk of resistance development in some insect populations against the insecticides that have been used repeatedly While the development of resistance is well understood, it is not easily predicted Therefore, insecticides must be used in conjunction with resistance management strategies in your area Consult your local or State agricultural advisors for details If insect resistance develops in your area, this product used alone may not provide sufficient levels of insect control If the reduction in control of insects cannot be associated to improper application timing, unfavorable weather conditions or abnormally high pest pressure, it is possible that a resistant strain may have developed 3 To reduce the potential for the development of resistance, alternate the use of this product in a rotation program with other classes of chemistry and modes of action Always make application of this product at the recommended use rates and in accordance with the use directions Do not apply less than recommended label rates either when applied alone or in tank mixtures For best performance, scout fields carefully and start applications when pests are smaller rather than larger If resistance is suspected, contact a local or State agricultural advisor
INTEGRATED PEST MANAGEMENT
Suro LFC may be used as part of an Integrated Pest Management (IPM) program that can include biological, cultural, and genetic practices aimed at preventing economic pest damage Application of this product should be based on IPM principles and practices including field scouting or other detection methods, correct target pest identification, population monitoring, and treating when target pest populations reach locally determined action thresholds Consult your State Cooperative Extension Service, professional consultants, or other qualified authorities to determine appropriate action treatment threshold levels for treating specific pest/crop systems in your area
CHEMIGATION USE DIRECTIONS
Make application of this product only through sprinkler irrigation systems: including center pivot, lateral move, end tow, side (wheel) roll, traveler, big gun, solid set, drip irrigation, or hand move irrigation systems For LEPA irrigation, application of a minimum of 075 inch of water per acre is recommended If a non-emulsified oil is used as the diluent, 1 to 2 pints per acre is the recommended use rate
RESTRICTIONS
• Do not make application of this product through any other type of irrigation system • Do not connect an irrigation system (including greenhouse systems) used for pesticide application to a public water system Proper calibration of chemigation equipment prior to application is important Improper calibration can lead to non-uniform spray and product distribution resulting in crop injury, lack of effectiveness or illegal residues in the crop Contact your State Agricultural Extension Service specialists, equipment manufacturers or other experts for consultation on the equipment set up and capability to obtain effective control of the target insect pests A person knowledgeable of the chemigation system and responsible for its operation, or under the supervision of the responsible person, shall shut the system down and make necessary adjustments should the need arise Failure to cease application during a mechanical stoppage may result in undesirable residues to adjacent areas The system must contain a functional check valve, vacuum relief valve, and low pressure drain appropriately located on the irrigation pipeline to prevent water source contamination from backflow The pesticide injection pipeline must contain a functional, automatic, quick-closing check valve to prevent the flow of fluid back toward the injection pump The pesticide injection pipeline must also contain a functional, normally closed, solenoid-operated valve located on the intake side of the injection pump and connected to the system interlock to prevent fluid from being withdrawn from the supply tank when the irrigation system is either automatically or manually shut down The system must contain functional interlocking controls to automatically shut off the pesticide injection pump when the water pump motor stops The irrigation line or water pump must include a functional pressure switch which will stop the water pump motor when the water pressure decreases to the point where pesticide distribution is adversely affected Systems must use a metering pump, such as a positive displacement injection pump (eg, diaphragm pump) effectively designed and constructed of materials that are compatible with pesticides and capable of being fitted with a system interlock Do not make application when wind speed favors drift beyond the treatment area Application of Suro LFC should be made continuously for the duration of the water application Dilute Suro LFC in sufficient volume to ensure accurate application over the treatment area When making application using chemigation, a minimum of 05 inch per acre of irrigation water is recommended Agitation is not typically required when a suitable diluent is used Conduct a compatibility test to make sure that phase separation will not occur during dilution and treatment Failure to achieve a uniform solution throughout the time of treatment may result in undesirable residues or less then desirable control
APPLICATION AND MIXING INSTRUCTIONS
Suro LFC is an insect control product that contains the active ingredient bifenthrin Suro LFC is formulated so that it can be mixed directly with water The rate of application is determined by pest pressure, timing of treatments and field scouting Use a lower listed use rate when there is low to moderate pest pressure, and a higher listed use rate under heavier pest pressure In areas where there is dry climate, application rates are typically higher
Tank Mix Preparation
Shake well before use - Begin agitation in the spray tank - Fill the tank one-half full with water - Add the specified amount of Suro LFC - Add the remaining water Maintain agitation until the application is complete If using nurse tanks, agitate the Suro LFC spray solutions in the tank before moving the solution to spray system
| Registered for cultures |
|---|
| Artichokes |
| Broccoli |
| Cabbage |
| Cauliflower |
| Brussels sprouts |
| Chinese cabbage |
| Kohlrabi |
| Mizuna |
| Red cabbage |
| Collard greens |
| Chinese broccoli |
| Mustard greens |
| Mustard spinach |
| Chinese mustard |
| Rape greens |
| Kale |
| Cabbages |